Description
Pramac GGW100G – 100 kVA Natural Gas Generator
Generac gas engine. Mecc Alte output. Ready as long as the gas is on.
The GGW100G gas generator delivers 100 kVA / 80 kW emergency standby and 90 kVA / 72 kW prime power from a Generac V8, 8900 cm³, naturally aspirated natural gas engine running at 1500 RPM with electronic ignition, 9.9:1 compression ratio and stoichiometric rich-burn combustion controlled by an exhaust lambda sensor. Output is delivered through a brushless Mecc Alte ECP34-1M/4C alternator at 400/230 V, 50 Hz, three phase, 0.8 power factor, with class H insulation, IP23 protection and DSR digital voltage regulation held inside 1%. Nominal current is 128.28 A, maximum 144.34 A, behind a 160 A circuit breaker. The engine needs an operating gas pressure of 1.7 to 4.0 kPa and draws 28.6 standard cubic metres of natural gas an hour at full standby load.
The canopy version is a galvanised sheet metal enclosure with high performance sound absorbing material, gasketed doors on steel hinges, wrapped exhaust piping, an exhaust silencer mounted in the upward facing discharge hood and a bottom power cable outlet, giving 68 dB(A) at 7 metres and a guaranteed sound power level of 97 dB(A). The canopy measures 3090 x 1130 x 1790 mm and weighs 1622 kg; the open version measures 2606 x 1122 x 1488 mm and weighs 1082 kg.
The GGW100G is controlled by a Deep Sea Electronics DSE G8600 controller in place of the Power Zone Pro, with an MPP modular parallel panel available as an option. At prime load it draws 21 standard cubic metres of natural gas an hour at 75% and 26.5 at 100%.
GGW100G at a glance
- 100 kVA / 80 kW emergency standby, 90 kVA / 72 kW prime power
- Generac V8 gas engine, 8900 cm³, naturally aspirated, 9.9:1 compression ratio, 1500 RPM, electronic ignition
- Mecc Alte ECP34-1M/4C brushless alternator, 4 pole, class H, IP23, DSR digital regulation inside 1%
- 400/230 V, 50 Hz, three phase, 0.8 power factor
- Nominal current 128.28 A, 160 A circuit breaker, 100 Ah battery, 12 V electric start
- Natural gas consumption 22.9 sm³/h at 75% and 28.6 sm³/h at 100% standby load; 21 and 26.5 sm³/h at 75% and 100% prime load
- Operating gas pressure 1.7 to 4.0 kPa
- Noise: 68 dB(A) @ 7 m, 79 dB(A) @ 1 m, guaranteed LWA 97 dB(A)
- Deep Sea Electronics DSE G8600 controller, MPP modular parallel panel optional
- Canopy 3090 x 1130 x 1790 mm, 1622 kg; open version 2606 x 1122 x 1488 mm, 1082 kg
Options include a coolant pre-heating system (PHS), three way catalytic muffler (CAT), upsized alternator (UAL), alternator anti-condensation heater (ACH), permanent magnet generator (PMG), genset metal nameplate (GMN), battery option (BAT), automatic lube oil top up system (ALS), different canopy colour (DCC) and four pole circuit breaker (TIF).
| POWER RATING | ||
| EMERGENCY STANDBY POWER ESP | kVA | 100 |
| EMERGENCY STANDBY POWER ESP | kW | 80 |
| PRIME POWER PRP | kVA | 90 |
| PRIME POWER PRP | kW | 72 |
| NOMINAL CURRENT | A | 128.28 |
| MAXIMUM CURRENT | A | 144.34 |
| CIRCUIT BREAKER | A | 160 |
| VOLTAGE | V | 400/230 |
| FREQUENCY | Hz | 50 |
| POWER FACTOR | cos φ | 0.8 |
| PHASES | 3 | |
| FUEL | Natural Gas | |
| ENGINE SPECIFICATIONS | ||
| ENGINE BRAND | Generac | |
| NR. OF CYLINDERS AND DISPOSITION | V8 | |
| DISPLACEMENT | cm³ | 8900 |
| COMPRESSION RATIO | 9.9:1 | |
| ASPIRATION | Naturally aspirated | |
| OPERATION SPEED NOMINAL | RPM | 1500 |
| IGNITION | Electronic | |
| ENGINE COOLING SYSTEM | Water | |
| COOLANT CAPACITY | l | 24 |
| ELECTRIC CIRCUIT | V | 12 |
| FUEL | Natural Gas | |
| EXHAUST GAS TEMPERATURE | °C | 596 |
| ALTERNATOR SPECIFICATIONS | ||
| ALTERNATOR BRAND | Mecc Alte | |
| MODEL | ECP34-1M/4C | |
| TYPE | Brushless | |
| POLES | 4 | |
| CLASS | H | |
| IP PROTECTION | 23 | |
| VOLTAGE REGULATION SYSTEM | DSR | |
| VOLTAGE TOLERANCE | % | 1 |
| GAS CONSUMPTION | ||
| NATURAL GAS CONSUMPTION @ 75% ESP | sm³/h | 22.9 |
| NATURAL GAS CONSUMPTION @ 100% ESP | sm³/h | 28.6 |
| NATURAL GAS CONSUMPTION @ 75% PRP | sm³/h | 21 |
| NATURAL GAS CONSUMPTION @ 100% PRP | sm³/h | 26.5 |
| OPERATING FUEL PRESSURE | kPa | 1.7 to 4.0 |
| REFERENCE GAS DENSITY | kg/sm³ | 0.73 |
| REFERENCE GAS HHV | MJ/sm³ | 38 |
| DIMENSIONS, WEIGHT AND NOISE | ||
| OPEN DIMENSIONS (L X W X H) | mm | 2606 x 1122 x 1488 |
| OPEN WEIGHT | kg | 1082 |
| CANOPY DIMENSIONS (L X W X H) | mm | 3090 x 1130 x 1790 |
| CANOPY WEIGHT | kg | 1622 |
| CANOPY GUARANTEED NOISE LEVEL LWA | dB(A) | 97 |
| CANOPY NOISE PRESSURE LEVEL @ 1 M | dB(A) | 79 |
| CANOPY NOISE PRESSURE LEVEL @ 7 M | dB(A) | 68 |
GGW Series – Natural Gas Generators
Clean-Burning. Reliable. Engineered for Standby Power.
The GGW Series is a range of natural gas generators built around Generac gas engines and Mecc Alte brushless alternators, packaged in an industrial canopy for facilities that want dependable, lower-emission standby or prime power from a mains gas connection. With no diesel to store or refresh, a gas generator is ready for as long as the outage lasts.
Key Features
- Generac gas engine with stoichiometric rich-burn combustion, lambda sensor and electronic pressure regulator with automatic air-fuel ratio control
- Primary and secondary fuel shutoff with DN32 PN6 flanged fuel connection
- Mecc Alte brushless alternator, class H, IP23, DSR digital voltage regulator
- Sound-attenuated galvanised enclosure with gasketed doors and upward facing discharge hood
- Power Zone Pro controller with 4.3 inch colour touch screen, NFPA 110 Level 1 compliant, Modbus and Ethernet communication
- Open and canopy versions available
Frequently Asked Questions
What gas pressure does a GGW generator need?
The operating fuel pressure and the gas consumption at each load are listed in the tables above for this model. Confirm supply pressure and capacity with your gas fitter before installation.
Can it be paralleled or connected to a transfer switch?
Yes. An automatic transfer switch (ATS) is available as an accessory, and the four pole circuit breaker (TIF), remote signalling contacts (TLP) and remote connection kit with antenna (RCG) are optional on the control panel.
How much gas does the GGW100G use?
At full standby load it draws 28.6 standard cubic metres of natural gas an hour, falling to 22.9 at 75% standby load. At prime rating the figures are 26.5 and 21 sm³/h, based on a reference gas of 0.73 kg per standard cubic metre and 38 MJ higher heating value. Supply pressure must be 1.7 to 4.0 kPa at the inlet.
Is an automatic transfer switch (ATS) included?
No. An automatic transfer switch is not included unless it is listed in the product description above. Ozwide Power can supply a correctly rated ATS with the generator, so ask for a package price when you enquire.