Description
Pramac GRW405V – 400 kVA Rental Diesel Generator
Volvo power. Leroy Somer output. 1180 litre tank. Rental tough.
The GRW405V diesel generator delivers 400 kVA / 320 kW emergency standby and 365 kVA / 292 kW prime power from a Volvo TAD1352GE, a six cylinder, 12.78 litre, turbocharged, water-cooled Stage IIIA engine running at 1500 RPM with electronic governor. Output is delivered through a brushless Leroy Somer LSA 46.3 L11 alternator at 400/230 V, 50 Hz, three phase, 0.8 power factor, with class H insulation, IP23 protection, Protection System 2 winding treatment, 12 winding leads and electronic voltage regulation held inside 0.5%. Maximum current is 577 A behind an 800 A circuit breaker. The set is switchable to 60 Hz for 1800 RPM operation.
The canopy is built from modular panels of zinced metal sheet tested to more than 1000 hours of salt spray, with gasketed access doors and lockable handles on each side, washable fireproof soundproofing and an integrated residential exhaust silencer with rain flap, giving 67 dB(A) at 7 metres and a guaranteed sound power level of 97 dB(A). The heavy-duty powder coated base frame is fully bunded to retain 110% of the set fluids and carries integrated fork pockets, a pull bar and a single lifting point with rung and handle on both sides. The unit measures 4165 x 1500 x 2130 mm and weighs 4515 kg.
The integrated 1180 litre metal fuel tank runs 19.98 hours at 75% prime power and 15.69 hours at full load, with a refilling point on each side and a six way fuel valve for connection to an external tank. The ACP automatic control panel carries the AMF function, full genset monitoring and protection, a detailed event log with time and date, emergency push button, analogue fuel level meter and mechanical hour counter, differential protection, battery charger and two wire remote start/stop. An MPP modular parallel panel is available as an alternative.
GRW405V at a glance
- 400 kVA / 320 kW emergency standby, 365 kVA / 292 kW prime power
- Volvo TAD1352GE, 6 cylinder in line, 12780 cm³, turbocharged, water cooled, Stage IIIA, 1500 RPM, electronic governor, 50/60 Hz switchable
- Leroy Somer LSA 46.3 L11 brushless alternator, 4 pole, 12 leads, class H, IP23, regulation inside 0.5%
- 400/230 V, 50 Hz, three phase, 0.8 power factor, maximum current 577 A, 800 A circuit breaker
- Fuel consumption 59.07 L/h at 75% PRP, 75.20 L/h at 100% PRP
- 1180 L integrated metal fuel tank, runtime 19.98 h at 75% PRP, 15.69 h at 100% PRP
- Noise: 67 dB(A) @ 7 m, 78 dB(A) @ 1 m, guaranteed LWA 97 dB(A)
- Control panel: ACP automatic mains failure or MPP modular parallel, specify when ordering
- 24 V electric start, 36 L oil capacity, 24 L coolant capacity
- Canopy 4165 x 1500 x 2130 mm, 4515 kg
Standard equipment includes a battery isolator (MBS), earth rod with cable, document holder, lube oil drain pump, six way fuel valve for external tank use, dual fuel refilling points, a leak proof tray with detector sensor and transport bumpers. Electrical options include a dual frequency switch (DFS), internal canopy lighting (ICL), control section lighting (CLS), DSE2157 output expansion module (ARM7), DSE890 MKII 4G gateway (RGW2), engine analogue gauges (EAG), insulation monitoring device (IMD), socket kit (SPK), Powerlock (PWL) and bus bar arrangement (ERDF). Mechanical options include pre-heating (PHS), water separator filter (WSP), hot parts protection (HPP), ATEX exhaust spark arrestor (ESA), air shut-off valve (ASV), baseframe bumpers (BFB) and quick fit fuel connectors (QFC, QFC1). A load transfer switch (LTS) is available for the ACP panel.
EC mark compliant to 2006/42/CE, 2014/30/UE, 2014/35/UE, 2000/14/EC, 97/68/EC and 2011/65 RoHS, built to EN 12100, EN 13857 and EN 60204 under ISO 9001, with G2 class load acceptance to ISO 8528-5.
| POWER RATING | ||
| EMERGENCY STANDBY POWER ESP | kVA | 400 |
| EMERGENCY STANDBY POWER ESP | kW | 320 |
| PRIME POWER PRP | kVA | 365 |
| PRIME POWER PRP | kW | 292 |
| MAXIMUM CURRENT | A | 577 |
| CIRCUIT BREAKER | A | 800 |
| VOLTAGE | V | 400/230 |
| FREQUENCY | Hz | 50 |
| POWER FACTOR | cos φ | 0.8 |
| PHASES | 3 | |
| FUEL | Diesel | |
| ENGINE SPECIFICATIONS | ||
| EXHAUST EMISSION LEVEL | Stage IIIA | |
| ENGINE BRAND | Volvo | |
| MODEL | TAD1352GE | |
| NR. OF CYLINDERS AND DISPOSITION | 6 in line | |
| DISPLACEMENT | cm³ | 12780 |
| ASPIRATION | Turbocharged | |
| ENGINE COOLING SYSTEM | Water | |
| SPEED GOVERNOR | Electronic | |
| OPERATION SPEED NOMINAL | RPM | 1500 |
| OIL CAPACITY | l | 36 |
| COOLANT CAPACITY | l | 24 |
| STARTING SYSTEM | Electric | |
| ELECTRIC CIRCUIT | V | 24 |
| FUEL | Diesel | |
| ALTERNATOR SPECIFICATIONS | ||
| ALTERNATOR BRAND | Leroy Somer | |
| MODEL | LSA 46.3 L11 | |
| TYPE | Brushless | |
| POLES | 4 | |
| CLASS | H | |
| IP PROTECTION | 23 | |
| VOLTAGE REGULATION SYSTEM | Electronic | |
| VOLTAGE TOLERANCE | % | 0.5 |
| FUEL TANK AND AUTONOMY | ||
| FUEL TANK CAPACITY (INTERNAL, METAL) | l | 1180 |
| FUEL CONSUMPTION @ 75% PRP | l/h | 59.07 |
| RUNNING TIME @ 75% PRP | h | 19.98 |
| FUEL CONSUMPTION @ 100% PRP | l/h | 75.20 |
| RUNNING TIME @ 100% PRP | h | 15.69 |
| DIMENSIONS, WEIGHT AND NOISE | ||
| CANOPY DIMENSIONS (L X W X H) | mm | 4165 x 1500 x 2130 |
| CANOPY WEIGHT | kg | 4515 |
| CANOPY GUARANTEED NOISE LEVEL LWA | dB(A) | 97 |
| CANOPY NOISE PRESSURE LEVEL @ 1 M | dB(A) | 78 |
| CANOPY NOISE PRESSURE LEVEL @ 7 M | dB(A) | 67 |
GRW Series – Rental Diesel Generators
Low Noise. Heavy-Duty Build. Engineered for Long-Duration Performance.
The GRW Series is a robust family of rental-grade diesel generators developed for sites that require low noise, extended running autonomy and dependable performance in all conditions. Purpose-built for rental fleets, construction, utilities, mining, events and mission-critical environments, the GRW range delivers reliable three phase power across a broad output spectrum.
With corrosion-resistant zinced steel canopies tested to 1000 hours of salt spray and fully bunded heavy-duty baseframes that retain 110% of all fluids, every GRW generator is engineered to withstand aggressive environments, harsh weather and long operating cycles. Large integrated fuel tanks with a refilling point on each side deliver long uninterrupted running, and a six way fuel valve allows connection to an external tank for even longer autonomy.
Key Features
- Perkins and Volvo engine options with Leroy Somer brushless alternators
- Dual frequency 50/60 Hz capability with optional voltage selector switches
- Standard and Extra Silent acoustic canopies with integrated residential silencer and rain flap
- Fully bunded base frame with integrated fork pockets and pull bar
- Single lifting point, battery isolator (MBS), earth rod, document holder and lube oil drain pump as standard
- ACP automatic or MPP modular parallel control panels, with site and road trailer options
Frequently Asked Questions
What is included as standard on a GRW rental generator?
Every GRW set ships with a heavy-duty powder coated base frame bunded to 110% of its fluids, fork pockets and a pull bar, a single lifting point with rung and handle, a battery isolator (MBS), an earth rod with cable, a document holder, a lube oil drain pump, a six way fuel valve for external tank use, double fuel refilling points and a leak proof tray with detector sensor.
Can it be trailer mounted?
Yes. A site trailer (STR), road trailer (RTR) and road trailer with height adjustable drawbar (RTR-B) are available as accessories, along with a load transfer switch (LTS) for the ACP panel.
How long will the GRW405V run on a full tank?
The 1180 litre integrated tank gives 19.98 hours at 75% prime power or 15.69 hours at full load, using 59.07 and 75.20 litres per hour respectively. The six way fuel valve allows an external tank to be connected for longer runs.
Is an automatic transfer switch (ATS) included?
No. An automatic transfer switch is not included unless it is listed in the product description above. Ozwide Power can supply a correctly rated ATS with the generator, so ask for a package price when you enquire.